Whirlpool Microwave Overheating


Reference Model: WMH53520CS-0


Problem: Microwave overheating after 2 or 3 minutes of running.


Diagnosis: The thermal cut off mounted to the magnetron may be breaking the circuit. If this is the case, one of the following issues may be the cause for malfunction:

- The magnetron cooling fan is running slowly or not at all

- The exhaust vent or magnetron cooling fan opening is blocked

- The magnetron is running hot and needs replacement

- The magnetron thermal cut off is faulty


Some microwave parts for our reference model#

Magnetron

Magnetron

Item Number W10818686

High limit safety thermostat

High limit safety thermostat

Item Number W10598693

Door switch, three terminal

Door switch, three terminal

Item Number W10727360

Microwave line fuse 20A 250V

Microwave line fuse 20A 250V

Item Number W10138793