Reference Model: WMH53520CS-0
Problem: Microwave overheating after 2 or 3 minutes of running.
Diagnosis: The thermal cut off mounted to the magnetron may be breaking the circuit. If this is the case, one of the following issues may be the cause for malfunction:
- The magnetron cooling fan is running slowly or not at all
- The exhaust vent or magnetron cooling fan opening is blocked
- The magnetron is running hot and needs replacement
- The magnetron thermal cut off is faulty
Item Number W10818686Magnetron
Item Number W10598693High limit safety thermostat
Item Number W10727360Door switch, three terminal
Item Number W10138793Microwave line fuse 20A 250V