Frigidaire dryer error codes:


Reference Model: None


These error code explanations can help you diagnose a problem with your Frigidaire dryer.

On models without a digital display, the four indicator lights--Drying, Cool Down, Wrinkle Rid and Clean Lint Filter--flash a number of times to indicate the first digit of the error code. The Start light flashes a number of times to indicate the second digit. The Start light flashes 10 times for the letter A, 11 for B, 12 for C and so on.



Code Meaning Possible Cause Possible Parts
E10 Electronic control board communication error Unplug the dryer for 5 minutes to reset the control board. Plug the dryer in and start a cycle. If the code appears, replace the electronic control board Electronic control board
E11 Electronic control board communication error Unplug the dryer for 5 minutes to reset the control board. Plug the dryer in and start a cycle. If the code appears, replace the electronic control board Electronic control board
E12 Electronic control board communication error Unplug the dryer for 5 minutes to reset the control board. Plug the dryer in and start a cycle. If the code appears, replace the electronic control board Electronic control board
E24 Thermistor error Unplug the dryer. Check the resistance of the thermistor (temperature sensor). It should measure around 50,000 ohms. If it's defective, replace it Thermistor
E25 Thermistor error Unplug the dryer. Check the resistance of the thermistor (temperature sensor). It should measure around 50,000 ohms. If it's defective, replace it Thermistor
E4A Long dry time The normal dry time for the cycle has been exceeded. This code usually indicates a problem with the heating system. Unplug the dryer and check the heating element or gas burner components. Replace any defective parts Heating system components
E5B No heat Unplug the dryer and check the heating system components. For an electric dryer, check the house circuit breakers to see if one has tripped. For a gas dryer, make sure that the gas supply cut-off valve is fully open Heating system components
E68 Stuck key on the electronic control board If you can't free the stuck key, replace the electronic control board Electronic control board
E8C Frequent high-limit thermostat trips The high limit thermostat trips if the dryer overheats. Clear any blockage in the exhaust vent. If the dryer heats constantly because a relay on the electronic control board is stuck, replace the electronic control board Electronic control board
EAF Electronic control board failure Unplug the dryer for 5 minutes to reset the control board. Plug the dryer in and start a cycle. If the code appears, replace the electronic control board Electronic control board



Frigidaire Dryer Parts





Related Links

  1. Frigidaire Dryer Fuse or Sensor Parts
  2. Frigidaire Dryer Heating Element
  3. Frigidaire Dryer Latch, Catch, Lock Parts